39
Raveon Technologies Corp.
7 = Transmit CW
8 = Transmit 1010101…
TT
Max Packet Size – Set the maximum number of bytes in an
over-the-air packet.
1 - 512
240
VB
Read DC input Voltage– Returns the DC input voltage
reading, in mV (12500 = 12.5VDC input).
None
none
VR
Firmware Version – Returns firmware version currently
loaded on the module.
Read Only, 3
characters
none
Xn
Show or Configure the Repeat Table – Set the addresses
that this unit will store-and-forward data to/from. n = 1, 2, 3, or
4 designating the entry in the table to show or edit..
Four parameters
aaaa bbbb cccc dddd where
aaaa=Source Address
bbbb = S.A. Mask
cccc = Destination Address
dddd = D.A. Mask
XR
Enable/Disable Store and Forward Repeating – 0=disabled,
1 – enabled.
0 or 1 0 (Off)
&F
Restore Factory – Restore the factory default values. This
command will not erase the calibration values. After this
command executes, the modem will still be in the CONFIG
mode.
none
** indicates values that are calibrated in the factory and are unit-specific. If the “Radio
Type” is changed, these will need to be re-calibrated.
8.9. Default Frequencies
Channel 1 464.500 MHz