Raveon RV-M7 Spécifications Page 54

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 67
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 53
RV-M7 Technical Manual
54
12.2 Calibration Commands
The following AT commands are used to calibrate the M7. Do not ever change these unless you
have been factory trained to do so.
AT
Command
Command Description
Parameters
Factory
Default
R0
Symbol Peak Deviation Set the peak FM deviation of the
transmit symbols. Note: This can be a negative number to
invert the modulation.
Range: -1000 1000
120**
R1
Select CD pin output signal CD may be RF carrier detect,
or modem data detect.
Range : 0 - 2
2 = Always assert CD
1 = Data CD
0 = RF CD
1
R2
Over-The-Air bit rate - This is the data rate the radio uses
to send data over the air. All RF modems in the network
must use the same over-the-air baud rate. Refer to
section 7.6 for information on how to set the OTA baud rate.
Range:
0 = 800 5 = 9600 2L
1 = 1200 6 = 19200 4L
2 = 2400 7 = 5142 2L
3 = 4800 8 = 9600 4L
4 = 8000 4L 9 = 2000 2L
3
R3
Serial Port time out Number of mS of no activity on the
serial port before transmitting the data in its buffer.
Range: 1 - 5000
20 (mS)
R5
Preamble length The number of bytes to send over-the-air
in the pre-amble.
Range: 3 - 255
4**
(Varies based
on data rate
and radio
type. 7 typical)
R8
Frequency Offset. Used to set the radio on the center of the
radio channel.
Range: -500 to +500
0**
R9
Modulation Balance.
Range: 0-100
20**
RA
Select RF CD output threshold This value is the RSSI
threshold where the carrier detect is asserted. Note: To force
CD always on, set this to 0, and R1 to RF Carrier Detect.
Range : 0-999
300**
12.3 Center Frequency
1. Key the transmitter with CW output using this command:
ATTD 7